Use this sequence for LP/TLP desks. Do not follow the ZP450 two-flash hold — that is a different printer family. ZP450 calibrate · QL calibrate.
- Set the driver or application to the media type you are using (Gap/Web or Black Bar / Mark). Send a test print while the button is green so the printer is configured. Cycle power if the button is red — the printer only accepts data when the light is green.
- Turn the printer off with media loaded.
- Hold the feed button down and turn the printer back on.
- When the red light starts flashing, release the feed button.
- The light turns green and the printer advances a few blanks.
- When it stops and prints internal information, press Feed once.
- You should get another label with an “Out of Dump” message. After that, one label should issue each time you press Feed.
Next: Load media (LP/TLP) · Self-test (LP/TLP)
Open Setup Studio for a guided path · Call (312) 416-1518 · Contact